1) “SAFETY OF TELECOM EQUIPMENT” |
Power interface/ Input current test |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 1.6) |
Rs.65,007/- |
Marking and Instructions |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 1.7 to 1.7.14) |
Protection From Electric Shock and Energy hazards |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 2.1) |
SELV circuits |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 2.2) |
Limited Current Circuits |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 2.4) |
Limited Power Source |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 2.5) |
Provision for Earthing and bonding |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 2.6) |
Over-Current And Earth Fault Protection In Primary Circuits |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 2.7) |
Safety Interlocks |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 2.8) |
Electrical insulation Electric strength test with preconditioning/ Humidity Conditioning |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 2.9) |
Clearances, Creepage Distances And Distances Through Insulation Clearances Creepage |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 2.10) |
Wiring Connection And Supply General |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 3.1) |
Connections to Mains Supply |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 3.2) |
Wiring Terminals For External Conductors |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 3.3) |
Disconnections From The Mains Supply |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 3.4) |
Interconnection of Equipment |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 3.5) |
Physical Requirements Stability |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 4.1) |
Steady Force |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 4.2.2 to 4.2.4) |
Impact & Drop Test |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 4.2.5 & 4.2.6) |
Stress relief test |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 4.2.7) |
Batteries |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 4.3.8) |
Protection against Hazardous moving parts |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 4.4) |
Thermal Requirement |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 4.5.1 to 4.5.5) |
Opening In Enclosure |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 4.6) |
Resistance To Fire |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 4.7.3) |
Touch current and protective conductor current |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 5.1) |
Abnormal operating and Fault Conditions |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 5.3) |
Voltage Surge Test |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 7.4.2) |
(1.2/50us) Impulse Test |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 1.5.7.2; 2.10.3.9) |
(10/700us) Impulse Test |
IEC 60950:2005+ A1:2009+A2:2013 (Clause 1.5.7.3, 6.2.2.1, 2.10.3.9) |
Requirement for the mounting means of rack-mounted equipment |
IEC 60950:2005+ A1:2009+A2:2013 (Annex DD) |
Household and home/office document/media shredder |
IEC 60950:2005+ A1:2009+A2:2013 (Annex EE) |